Fluke 902 FC True-RMS HVAC Clamp Meter
Quantity
-
DetailINCLUDES:
• (1) 902 FC Clamp Meter
• (1) Pair TL75 Test Leads
• (1) 80BK Integrated DMM Temperature Probe
• (2) AA Alkaline Batteries
• (1) Soft Carrying Case
• (1) Quick Reference Guide
FEATURES:
• A wireless Fluke Connect-enabled clamp meter designed specifically for the needs of HVAC technicians
• Offers 200 µA DC current measurements to measure flame rod
• Extends resistance range to measure thermistors up to 60k?
• Captures flue gas temperature
• Measures start and run motor capacitors
• Measures variable frequency drive performance
• Ergonomic design fits in your hand and can be used while wearing personal protective equipment
• Large, easy-to-read backlit display improves readings in low light settings
• Connects to your smartphone via Fluke Connect so you can read measurements at a safer distance
• Measures AC current to 600 A and AC and DC voltage to 600 V
• Measures capacitance to 1000 µF and DC current to 200 µA
• Measures temperature from -10 °C to 400 °C (14 °F to 752 °F)
• Offers True-RMS voltage and current measurements to accurately measure non-linear signals
• Measures resistance to 60 k?
• Offers Min/Max recording to capture variations automatically
• Runs on two AA alkaline batteries
SPECIFICATIONS:
• A ac (via Jaw) Resolution: 0.1 A
• A ac (via Jaw) Accuracy: 2.0% ±5 Digit (45-65 Hz), 2.5% ±5 digit (65-400 Hz)
• A ac (via Jaw) Range: 600.0 A
• A ac (via Jaw) Crest Factor (50Hz or 60Hz): 2.5 MIN@220 A, > 1.4 MIN@600 A, Add 2% for CF>400 A
• V ac Resolution: 0.1 V
• V ac Accuracy: 1.5% ±5 Digits
• V ac Range: 600.0 V
• V dc Resolution: 0.1 V
• V dc Accuracy: 1.5% ±5 Digits
• V dc Range: 600.0 V
• Ohms Resolution: 0.1/1/10
• Ohms Accuracy: 1% ±5 Digits
• Ohms Range: 600/6000/60.00 k?
• Capacitance Resolution: 0.1/1 µF
• Capacitance Accuracy: 1% ±4 Digits
• Capacitance Range: 100.0/1000 µF
• µA Resolution: 0.1 µA
• µA Accuracy: 1% ±5 Digits
• µA Range: 200 µA
• Contact Temperature Resolution: 0.1 C/F
• Contact Temperature Accuracy: 1% ±8 Digits
• Contact Temperature Range: -40 to 400 °C (-40 °F to 752 °F)
• Beeper Volume: 75 dBA nom. 15 cm. from Case Front
• On Threshold: <=30 ?
The Fluke 902 FC Clamp Meter, with Fluke Connect wireless connectivity, can help HVAC technicians improve productivity in the field. The rugged dual-rated CAT III 600 V, CAT IV 300 V meter equips you to perform many essential HVAC system measurements: microamps for testing pilot light sensors; resistance up to 60 k?; AC current and AC/DC voltage; capacitance; and contact temperature, all with just one tool. Plus its small form factor makes it easy to hang on to and navigate in tight work spaces. -
Customer ReviewsNo comments