Home / Fluke / Fluke 1587/I400 FC 2-in-1 Insulation Multimeter with Current Clamp Kit

Fluke 1587/I400 FC 2-in-1 Insulation Multimeter with Current Clamp Kit

Quantity
ADD TO CART
BUY IT NOW
  • Detail
    INCLUDES:
    • (1) Fluke 1587 FC Insulation Multimeter
    • (1) Fluke i400 AC Current Clamp
    • (1) Crocodile Clips
    • (1) Test Probes
    • (1) Test leads
    • (1) Remote probe
    • (1) Type K Thermocouple
    • (1) Instruction CD
    • (1) Hard Carry Case

    FEATURES:
    • With the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease
    • Use the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuit
    • Pl/DAR measurements with TrendIt graphs
    • Memory storage through Fluke Connect Measurements app
    • Temperature Compensation through Fluke Connect Measurements app
    • VFD low-pass filter for accurate motor drive measurements
    • Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
    • Insulation test voltages 500 V, 1000 V
    • Insulation test: 0.01 M? to 2.0 G?
    • Insulation test: 0.1 M? to 600 M?
    • Auto-discharge of capacitive voltage

    SPECIFICATIONS:
    • AC Voltage Measurement Range: 600.0 Mv, 6.000 V, 60.00 V, 600.0 V, 1000 V
    • AC Voltage Measurement Resolution (0.1 Mv) Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3), Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3), Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3), Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3), Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(2% + 3)
    • AC Voltage Measurement Resolution (0.1 Mv) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts): ±(2% + 3), Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts): ±(2% + 3), Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts): ±(2% + 3), Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts): ±(2% + 3)¹, Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
    • Low-Pass Filter Voltage Range: 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V
    • Low-Pass Filter Voltage Resolution (0.1 mV) Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3), Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3), Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3), Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3), Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(2% + 3)
    • Low-Pass Filter Voltage Resolution (0.1 mV) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% - 3), Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3), Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3), Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3), Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(2% + 3)
    • Low-Pass Filter Voltage Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% - 3), Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% - 3), Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% - 3), Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% - 3), Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% - 3)
    • DC Voltage Measurement Range: 6.000 V dc, 60.00 V dc, 600.0 V dc, 1000 V dc
    • DC Voltage Measurement Resolution: 0.001 V, 0.01 V, 0.1 V, 1 V
    • DC Voltage Measurement Accuracy ±(% of Rdg + Counts): ±(0.09% + 2), ±(0.09% + 2), ±(0.09% + 2), ±(0.09% + 2)
    • Input Impedance: 10 M? (Nominal), <100 pF
    • Normal Mode Rejection Ratio: >60 dB @ 50 Hz or 60 Hz
    • Common Mode Rejection Ratio: >120 dB @ dc, 50 Hz or 60 Hz (1 k Unbalance)
    • DC Millivolts Measurement Range: 600.0 mVdc
    • DC Millivolts Measurement Resolution: 0.1 mV
    • DC Millivolts Measurement Accuracy ±(% of Rdg + Counts): ±(0.1% + 1)
    • DC and AC Current Range (AC 45 Hz to 1000 Hz): 400 mA
    • DC and AC Current Resolution: 0.1 mA
    • DC and AC Current Accuracy ±(% of Rdg+Counts): ±(1.5% + 2)¹
    • DC and AC Current Burden Voltage (Typical): 2 mV/mA
    • DC and AC Current Range: 60 mA
    • DC and AC Current Resolution: 0.01 mA
    • DC and AC Current Accuracy ±(% of Rdg+Counts): ±(1.5% + 2)¹
    • DC and AC Current Burden Voltage (Typical)L 2 mV/mA


    This Current Clamp is a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, helping you take measurements safely with industry standard safety ratings.
  • Customer Reviews
    No comments